Transducer Model Specification

PenMet 014

PenMet 014L

PenMet 016

PenMet 018

Range: Liquids

            Solids

0.5-15 metres

0.5-9 metres

0.5-20 metres

0.5-13 metres

0.3-10 metres

0.3-6 metres

0.25-6 metres

0.25-4metres

Resolution

2mm

2mm

1mm

1mm

Transmission Frequency

38kHz

38kHz

60kHz

80kHz

Transmission beam ½ angle

6 degrees

6 degrees

6 degrees

6 degrees

Environment Protection

IP68

IP68

IP68

IP68

Ex Protection

EEx m II T6

EEx m II T6

EE x m II T6

EE x m II T6

Mounting standards

M20 or

4″ NP 16  Flange

M20 or

 4″ NP 16 Flange

M20 or

4″  NP 16 Flange

M20 or

 3″ NP 16 Flange

Available housing materials and Temperature
limits:

HDPE

(-40C to +60C)

PTFE

(-40 to +140C)

HDPE

(-40C to +60C)

PTFE

(-40 to +140C)

HDPE

(-40C to +60C)

PTFE

(-40 to +140C)

HDPE

(-40C to +60C)

PTFE

(-40 to +140C)