flomag spec

FloMag Specifications

Back | Specifications | Data Sheet

 

Specification

Technical Data

Nominal Size DN

10 / 1200

Nominal Pressure PN

6, 10, 16, 25, 40

Min. conductance of measured liquid

5 ųS/ cm

Material of electrodes

Stainless steel, Hastelloy – C4, Pt

Environment Temperature

-5 °C / +55 °C

Sensor Lining

Soft or hard rubber, PTFE

Version

Separate or compact version

Connection

Flange, wafer, threaded

Max. temperature of measured liquid

Up to + 150 °C

Max. error of measurement

Less than 0,5% for 5/100% qs

Less than 1% for 1/5% qs

Measurement Range

0,1 / 10m/s

Outlets

Current 0(4) / 20mA (0 / qs) with galvanic separation

Frequency 0 / 1000 l/pulse with galvanic separation

Data transfer RS 232, RS 485

Power Supply

230 V ± 10%, 50 Hz (AC) or 24 V (DC)

Protection

IP 67